A Flygt submersible sewage pump carries two seals on one shaft: a lower seal facing the pumped media and an upper seal running in the oil chamber. The pair is replaced together, the lower seal takes the abrasive duty, and the upper seal has to survive oil rather than water. Shaft sizes are 20, 25 and 35 mm, with the 3102 and 3085 casings dominating demand.

Victor supplies upper and lower seals for Flygt 3102, 3085, 3126, 2084, 2135, 2151 and 2201 pumps and for the 2650, 4630 and 4660 mixers, in plug-in, cartridge and Griploc form with matching O-ring kits.

Seal types used on Flygt pumps

The 3102 uses a 25 mm shaft with a multi-spring upper and lower pair, listed as Flygt 7, with Flygt 10 the same duty built to the Grindex FJL-25 reference. The 3085 runs a 20 mm shaft: Flygt-6 covers the 3085-91 to 3085-890 variants and Flygt 8 replaces the Griploc version.

The 3126, 2084, 2135, 2151 and 2201 take a 35 mm shaft with TC faces on TC and Viton elastomer, catalogued as Flygt 11 with the FKL-35 code and Flygt 12 with FKU-35. Plug-in designs such as Flygt-3 are preset with setting clips and need no pump modification.

How to identify the right replacement

A Flygt model number is only a start; one model runs several impeller trims. Confirm the position first: an upper seal with a dry oil-side face and a lower seal exposed to sewage are not interchangeable even at the same shaft size. Installing the pair correctly matters as much as the part number, since a folded O-ring passes a bench test and fails in the sump.

  • Nameplate: model, variant and serial; a 3085-120 and a 3085-280 can use different seal heights.
  • Shaft size: 20 mm on 2075, 3057, 3067, 3068 and 3085; 25 mm on 2650, 3102, 4630 and 4660; 35 mm on 3126, 2084, 2135, 2151 and 2201.
  • Position: upper or lower, and whether the kit is a matched pair with both seals plus the O-ring.
  • Face material: TC on TC for raw sewage; carbon on ceramic appears on cleaner duties and wears faster on grit.
  • Elastomer: Viton on the oil side, NBR or EPDM where the pumped media calls for it.

Materials and duty limits

Sewage duty runs tungsten carbide against tungsten carbide with Viton, and that tolerates grit far better than carbon. Where the media is mildly acidic, SiC faces with EPDM or FKM do the same job with better corrosion resistance. Cartridge versions are rated near 1.2 MPa and 10 m/s; in a lift station the ceiling is usually oil chamber temperature.

Temperature limits follow the rubber: about −30 °C to +180 °C on Viton, tighter on NBR. Springs and stampings are stainless 304 or 316, with hastelloy C and AM350 available.

What we supply for Flygt pumps

Cross-reference notes

Interchange codes here come from our own listings. Flygt 8 and Flygt 9 are both Griploc pattern seals, the first for 20 mm pump shafts and the second for 25 mm shafts on pumps and mixers. Flygt 10 carries the Grindex FJL-25 reference, Flygt 11 the FKL-35, Flygt 12 the FKU-35, and Flygt-5 is listed as a replacement for ITT cartridge seals. Nothing beyond these listings is claimed as an equivalent.

FAQ

Should the upper and lower seal always be replaced together?

Yes. Both share one oil chamber, and grit that reaches the lower seal usually reaches the upper one too. Replacing only one leaves a worn partner in the same oil.

Can a plug-in seal replace a Griploc seal?

Only where the housing and shaft match. Plug-in seals are preset and use an aluminium alloy seat, while Griploc parts fit differently; check seat bore and shaft size first.