Allweiler SPF pumps are three-screw pumps, and the rotor set is the matched group of one power rotor and two idlers that generates the flow. SPF10 and SPF20 pumps in this category carry a three-part code, so an SPF10 38 and an SPF10 56 take different sets even when the casings look alike. Sets are listed under Allweiler part numbers 500598, 55312, 55113, 55292 and 618877.
Victor supplies rotor sets for Allweiler SPF10 and SPF20 pumps in the 38, 46 and 56 sizes. Each set is built to the size code and matched as a group, not as individual rotors that happen to fit.
SPF20 pumps appear in the 46 and 56 sizes, listed as 55312 for SPF 20 46 and 500598 for SPF 20 56. SPF10 pumps run the 38, 46 and 56 sizes, listed as 55292, 55113 and 618877.
The size code after SPF is not a flow rating. It fixes rotor diameter and rotor length, which is why a set from a 46 housing will not restore performance in a 56 housing, and why the part number has to come from the pump code rather than from the pipe size.
Identify the pump from the full code on the nameplate, then confirm against the part number on the old rotor. When the nameplate is gone, measure the power rotor diameter, the idler diameter and the rotor length, and check the housing bore for scoring. What a rotor set does inside a pump explains why those three measurements decide the fit.
Rotor and idler surfaces are hardened steel against a cast housing, and the hydraulic fit is the lapped clearance between them. That clearance is what a new set restores. Clean oil keeps it; abrasive grit and water in the oil open it and the flow curve falls away.
Temperature comes from the pumped oil and pressure from rotor length and the number of starts. A set built for a 38 length will not hold the pressure of a 56 in the same casing, so matching the code matters more than matching the bore.
Cross-referencing here runs on Allweiler part numbers alone. 500598 covers SPF 20 56 and 55312 covers SPF 20 46, while the SPF10 line splits three ways: 55292 for the 38, 55113 for the 46 and 618877 for the 56. Two SPF sets can share a part-number prefix and still differ in rotor length, so a number from another SPF10 pump is not a safe substitution.
Only if the housing bore and the rotor surfaces are still within tolerance. Once the lapped clearance has opened, reworking the rotors removes the case hardness and the set fails again quickly.
That is the usual signature of a worn rotor set. Internal leakage past the rotors costs flow first; discharge pressure only drops once the clearance is badly open.





For inquiries about our products or pricelist, please leave your email to us and we will be in touch within 24 hours.
About Victor
Contact Victor