Lowara SV and e-SV multistage pumps and the smaller centrifugal models run compact seals on 12, 16, 22 and 26 mm shafts, and the family stays at or below 8 bar. That low rating is the first thing to note: these seals are built for clean water, pressure boosting and water treatment, not for high-pressure service. The second is the Roten reference, because several Lowara builds use a Roten 5 or UNE5 seal in the same housing.
Victor supplies LWR-1, LWR-2, LWR-3 and LWR-4 in 12, 16, 22 and 26 mm, covering the SV and e-SV pumps and the smaller Lowara centrifugal models.
LWR-1 and LWR-2 are the 12 mm and 16 mm seals, listed as replacements for Roten 5-12 mm and 5-16 mm. LWR-3 is the 16 mm version for the Roten UNE5-16 mm housing, which uses different seat retention from the 5 series.
LWR-4 covers the SV and e-SV multistage pumps in 22 mm and 26 mm, with face options from graphite against aluminium oxide up to SiC against SiC for harder water. All four patterns are single seals with an O-ring secondary seal and a stainless spring.
Shaft size and the Roten reference decide most orders. The 16 mm shaft appears in two different seals, 5-16 and UNE5-16, and they are not interchangeable because seat bore and spring height differ. Whether the seal can run dry matters on booster sets, where a dry run at start-up is the usual cause of failure.
The 12 and 16 mm seals run carbon, SiC or TC faces against ceramic, SiC or TC seats with NBR, EPDM, Viton, Aflas or FEP rings, rated to 8 bar and 10 m/s. Temperature runs from −20 °C to +200 °C depending on the elastomer.
LWR-4 adds graphite against aluminium oxide for clean water, SiC against SiC for harder water, and FEP or FFKM for chlorinated and hot water. Metal parts are 304 or 316 stainless throughout, and the 22 and 26 mm sizes share one seat family.
The equivalences on this page come from our own listings. LWR-1 replaces Roten 5-12 mm, LWR-2 the Roten 5-16 mm, and LWR-3 the Roten UNE5-16 mm, which is a different housing despite sharing the 16 mm shaft. LWR-4 is listed against the SV and e-SV pumps by model rather than by a Roten number, and the 22 and 26 mm sizes are ordered by shaft measurement.
Not reliably. Both are 16 mm seals, but the UNE5 housing has a different seat bore, so the seal will not sit at the right height.
Dry running. A multistage booster that loses suction runs the faces without a film, and carbon on ceramic will not survive that for long.
For inquiries about our products or pricelist, please leave your email to us and we will be in touch within 24 hours.
About Victor