Lowara SV and e-SV multistage pumps and the smaller centrifugal models run compact seals on 12, 16, 22 and 26 mm shafts, and the family stays at or below 8 bar. That low rating is the first thing to note: these seals are built for clean water, pressure boosting and water treatment, not for high-pressure service. The second is the Roten reference, because several Lowara builds use a Roten 5 or UNE5 seal in the same housing.

Victor supplies LWR-1, LWR-2, LWR-3 and LWR-4 in 12, 16, 22 and 26 mm, covering the SV and e-SV pumps and the smaller Lowara centrifugal models.

Seal types used on Lowara pumps

LWR-1 and LWR-2 are the 12 mm and 16 mm seals, listed as replacements for Roten 5-12 mm and 5-16 mm. LWR-3 is the 16 mm version for the Roten UNE5-16 mm housing, which uses different seat retention from the 5 series.

LWR-4 covers the SV and e-SV multistage pumps in 22 mm and 26 mm, with face options from graphite against aluminium oxide up to SiC against SiC for harder water. All four patterns are single seals with an O-ring secondary seal and a stainless spring.

How to identify the right replacement

Shaft size and the Roten reference decide most orders. The 16 mm shaft appears in two different seals, 5-16 and UNE5-16, and they are not interchangeable because seat bore and spring height differ. Whether the seal can run dry matters on booster sets, where a dry run at start-up is the usual cause of failure.

  • Pump model: SV, e-SV or the smaller centrifugal model, plus the stage count.
  • Shaft diameter: 12, 16, 22 or 26 mm.
  • Roten reference: 5-12, 5-16 or UNE5-16 for the 12 and 16 mm builds.
  • Face pair: carbon on ceramic or aluminium oxide for clean water, SiC on SiC for hard water.
  • Elastomer: EPDM for water, FKM or FFKM where the water is chlorinated or hot.
  • End play: the seal allows about ±1.0 mm, so check shaft float after a bearing change.

Materials and duty limits

The 12 and 16 mm seals run carbon, SiC or TC faces against ceramic, SiC or TC seats with NBR, EPDM, Viton, Aflas or FEP rings, rated to 8 bar and 10 m/s. Temperature runs from −20 °C to +200 °C depending on the elastomer.

LWR-4 adds graphite against aluminium oxide for clean water, SiC against SiC for harder water, and FEP or FFKM for chlorinated and hot water. Metal parts are 304 or 316 stainless throughout, and the 22 and 26 mm sizes share one seat family.

What we supply for Lowara pumps

Cross-reference notes

The equivalences on this page come from our own listings. LWR-1 replaces Roten 5-12 mm, LWR-2 the Roten 5-16 mm, and LWR-3 the Roten UNE5-16 mm, which is a different housing despite sharing the 16 mm shaft. LWR-4 is listed against the SV and e-SV pumps by model rather than by a Roten number, and the 22 and 26 mm sizes are ordered by shaft measurement.

FAQ

Will a 16 mm LWR-2 fit a pump that takes UNE5-16?

Not reliably. Both are 16 mm seals, but the UNE5 housing has a different seat bore, so the seal will not sit at the right height.

Why do Lowara booster seals fail so often?

Dry running. A multistage booster that loses suction runs the faces without a film, and carbon on ceramic will not survive that for long.