Grundfos multistage pumps are built around a few shaft sizes, and the seal is decided by shaft diameter plus the way it is retained. CR, CRN and CRI vertical pumps use 12, 16 and 22 mm shafts in the small frames and 32 mm and up on CR32 to CR90; the SA range carries a long-type seal on 50 and 60 mm shafts. The seal sits behind the impeller stack and drains to a weep hole in the lantern, so wear shows up there first.
Victor supplies single spring, multi spring, semi-cartridge and clipped cartridge seals for these families. The same 12 and 16 mm interfaces appear on CDL and CNP multistage pumps, so a seal bought for a CDL12 or CDL16 usually crosses straight over.
The CR/CRN/CRI cartridge is preset to working length with setting clips and slides on as one unit, so the impeller stack stays assembled. Semi-cartridge Type H and Type B seals use a threaded hex head that screws into the housing and an O-ring running on the shaft.
Type H fits CR1, CR3, CR5, CRN1, CRN3, CRN5, CRI1, CRI3, CRI5 and the CR32 to CR90 families; Type B covers CH, CHI, CHE, CRK, SPK, TP, AP, NK, LM, NM, NP and DNM lines. The SA long-type seal reaches the impeller hub on 50 and 60 mm shafts.
Start with the pump type code, then confirm on the bench. A CR10-5 and a CRN32-4 share nothing at the seal, and the frame number decides between a 12 mm and a 32 mm unit. Measuring the old seal before it is scrapped settles the rest.
Clean water duty on CR and CDL pumps runs carbon against SiC or ceramic with EPDM, rated near 1 MPa and 10 m/s on 12 and 16 mm sizes. Glycol loops and hot water move to SiC against SiC or tungsten carbide with FKM. The 22 mm GLF-14 reaches 180 °C at 1 MPa, and SA long-type seals go to 2.5 MPa at 180 °C.
Mildly corrosive fluid is handled better by SiC/SiC faces and FKM or FFKM rings than by a larger seal. Every pattern we list stays below 2.5 MPa, and the elastomer sets the temperature ceiling.
Cross-reference data here comes from our own product records. The Grundfos-6 lower seal is listed against AES M010SA for the lower position on larger CR and CRN builds. Everything else in the Grundfos list is matched on type code, shaft size and face combination, so quote the pump code and the shaft measurement.
On cartridge builds, yes: the clipped cartridge is preset and slides on as one piece. Semi-cartridge Type H and B seals need the housing off to reach the seat.
Usually a seat pressed too deep or an O-ring pinched on a sharp shaft shoulder. Both alter the spring load or leave a leak path, and both appear within the first hour of running.
For inquiries about our products or pricelist, please leave your email to us and we will be in touch within 24 hours.
About Victor
Contact Victor