Features
• Resilient single spring, rubber Diaphragm Seal
• Supplied with a Type 20 boot-mounted stationary as standard
• Designed to suit original common UK housing sizes.
Operating Limits
• Temperature: -30°C to +150°C
• Pressure: Up to 8 bar (116 psi)
• For full Performance Capabilities please download data sheet
Limits are for guidance only. Product performance is dependent on materials and other operating conditions.
d stationary to fit same housing sizes and working lengths.
Combination Materials
Stationary Ring: Ceramic/Carbon/SIC/SSIC/TC
Rotary Ring: Ceramic/Carbon/SIC/SSIC/TC
Secondary Seal: NBR/EPDM/Viton
Spring and Punched Parts:SS304/SS316
W20 data sheet of dimension(mm)
| Size/Metric | D3 | D31 | D7 | L4 | L3 |
| 10 | 22.95 | 20.5 | 24.6 | 8.74 | 25.6 |
| 11 | 23.9 | 22.8 | 27.79 | 8.74 | 25.6 |
| 12 | 23.9 | 24 | 27.79 | 8.74 | 25.6 |
| 13 | 26.7 | 24.2 | 30.95 | 10.32 | 25.6 |
| 14 | 26.7 | 26.7 | 30.95 | 10.32 | 25.6 |
| 15 | 26.7 | 26.7 | 30.95 | 10.32 | 25.6 |
| 16 | 31.1 | 30.4 | 34.15 | 10.32 | 25.6 |
| 18 | 31.1 | 30.4 | 34.15 | 10.32 | 25.6 |
| 19 | 33.4 | 30.4 | 35.7 | 10.32 | 25.6 |
| 20 | 33.4 | 33.4 | 37.3 | 10.32 | 25.6 |
| 22 | 39.2 | 33.4 | 40.5 | 10.32 | 25.6 |
| 24 | 39.2 | 38 | 40.5 | 10.32 | 25.6 |
| 25 | 46.3 | 39.3 | 47.63 | 10.32 | 25.6 |
| 28 | 49.4 | 42 | 50.8 | 11.99 | 33.54 |
| 30 | 49.4 | 43.9 | 50.8 | 11.99 | 33.54 |
| 32 | 49.4 | 45.8 | 53.98 | 11.99 | 33.54 |
| 33 | 52.6 | 45.8 | 53.98 | 11.99 | 33.54 |
| 35 | 52.6 | 49.3 | 53.98 | 11.99 | 33.54 |
| 38 | 55.8 | 52.8 | 57.15 | 11.99 | 33.54 |
| 40 | 62.2 | 55.8 | 60.35 | 11.99 | 33.54 |
| 42 | 66 | 58.8 | 63.5 | 11.99 | 40.68 |
| 43 | 66 | 58.8 | 63.5 | 11.99 | 40.68 |
| 44 | 66 | 58.8 | 63.5 | 11.99 | 40.68 |
| 45 | 66 | 61 | 63.5 | 11.99 | 40.68 |
| 48 | 66.6 | 64 | 66.7 | 11.99 | 40.68 |
| 50 | 71.65 | 66 | 69.85 | 13.5 | 40.68 |
| 53 | 73.3 | 71.5 | 73.05 | 13.5 | 41.2 |
| 55 | 78.4 | 71.5 | 76 | 13.5 | 41.2 |
| 58 | 82 | 79.6 | 79.4 | 13.5 | 41.2 |
| 60 | 82 | 79.6 | 79.4 | 13.5 | 41.2 |
| 63 | 84.9 | 81.5 | 82.5 | 13.5 | 41.2 |
| 65 | 88.4 | 84.6 | 92.1 | 15.9 | 49.2 |
| 70 | 92.6 | 90 | 95.52 | 15.9 | 49.2 |
| 73 | 94.85 | 92 | 98.45 | 15.9 | 49.2 |
| 75 | 101.9 | 96.8 | 101.65 | 15.9 | 49.2 |
Description
W20 Single spring mechanical seals replace Vulcan Diaphragm Type 20 is a like-for-like replacement unit for standard pump seal chambers. It is normally specified for pulp and paper process water. Bore and shaft tolerances follow the original part, so no adaptor is needed.
Internally the seal uses a single coil spring driving the seal through one central load path. The face pair is silicon carbide running on carbon graphite; secondary seals are FKM.
It is approved for -30 °C to 150 °C, up to 8 bar and 25 m/s at the faces. Keep the faces clean during fitting; a single grit particle will open a leak path.
Check the shaft for wear at the secondary seal track and the chamber for scoring before the new unit goes on. The first signs of wear are a slow leak at the secondary seal and a light polish on the faces.
EPDM covers water and dilute chemical service but not mineral oils; FKM handles oils, fuels and many solvents; FFKM is reserved for aggressive media where the softer elastomers swell. Fitting a complete replacement keeps the face load and working height as they left the factory, rather than rebuilding the stack on site. Keeping one unit on the shelf cuts the downtime that follows a leak, since the pump does not have to wait for a part to arrive.
Send the nameplate data with the model and shaft size, and the unit is checked against the original drawing. The unit belongs to the mechanical seal manufacturer line. Related units in the same family include Vulcan Type 96 Parallel O-Ring Mounted Mechanical Seals and W155 O-ring single spring pump seals replace Burgmann BT-FN. Include the quantity and the required elastomer option with the enquiry.
The reference carried by this unit is W20. Confirm that reference against the pump nameplate and the shaft size before the order is placed, since later versions of the same pump can use a different seal arrangement.