Description

AES P02 Elastomer Bellow Mechanical Seal John Crane Type 2 N SEAT is a like-for-like replacement unit for standard pump seal chambers. It is normally specified for food and beverage process lines. Bore and shaft tolerances follow the original part, so no adaptor is needed.

The design is built around an elastomer bellows that seals on the shaft without a separate gasket. Standard build pairs carbon graphite with silicon carbide faces and NBR O-rings.

Exact limits follow the face material and elastomer choice; confirm the duty point against the datasheet for the specific build. A short dry run is enough to score the faces, so prime the chamber before start-up.

Measure shaft diameter, chamber depth and working height before stripping the old unit; the new seal is set to those numbers, not to the dimensions of the worn part. A seal that has run dry shows heat colouring on the faces before it shows a leak.

As a rule, EPDM suits water-based duty, FKM suits oils and fuels, and FFKM is used where solvents would swell the other two. Replacing the complete unit rather than single components avoids re-setting the working height, which is where most repeat failures start. A spare on site is worth holding for critical pumps, where a leaking seal takes the whole line out of service.

Quote the pump model, shaft diameter and medium when enquiring, and the seal is matched to the original part number. The unit belongs to the pump mechanical seal line. Two close alternatives are W2100 Elastomer Bellow Mechanical Seal Replacement of John Crane 2100 and W502 John Crane Type 502 Replacement Unitized Elastomer Bellows Seal For Pumps. Include the quantity and the required elastomer option with the enquiry.

The reference carried by this unit is P02. Confirm that reference against the pump nameplate and the shaft size before the order is placed, since later versions of the same pump can use a different seal arrangement.